Project design

    Hybrid Inverter Super-Backup Function

    Introduction

    This article will introduce the Super-Backup Function on Solax Hybrid inverters. With the Super-Backup function, during black-out the inverter can supply the backup loads even if there are no batteries installed.

    Different from the normal backup solution with batteries, the Super-Backup solution, during EPS Mode, hybrid inverters export power only from PV panels (without batteries). As the PV input power is not stable, there will be some limitation. In order to avoid the overload, the EPS ports (back-up loads) must be followed:

    1. For single-phase inverters(X1-Hybird-G4 as an example), the output power of EPS ports is restricted to half (50%) of the nominal output power of EPS ports (with battery). For more details in the Table1 below.

    2. For three-phase inverters(X3-Hybird-G4 as an example), the output power of EPS ports is restricted to half (50%) of the nominal output power of EPS ports (with battery) total phase, but there are some differences about per-phase power. For more details in the Table2 below.

    Notes:

    1. If PV input power is sufficient, there will not be any trouble. But if PV input power is not enough, an “EPS Overload” will be reported on the LCD.

    Advantages

    Some customers install the hybrid inverter first as a string inverter (Battery Ready) and add the batteries later, now they can use the back-up without battery.

    Configuration

    Setting path:

    Main → Settings → Advance Setting → EPS Setting → Super-Backup

    This function is Disable by default.

    If users want to supply EPS loads only with PV, just Enable it.

    Compatibility

    Hardware version:

    Function

    Model

    Super-Backup

    X1-Hybrid G4

    X3-Hybrid G4

    X1-IES

    X3-IES

    X3-ULTRA

    X3-AELIO

    X3-HYB-G4 PRO

    Software version(latest version):

    Model

    ARM

    DSP

    X1-Hybrid G4

    ≥1.44

    ≥1.48

    X3-Hybrid G4

    ≥1.44

    ≥1.47

    X1-IES

    009.12

    013.12

    X3-IES

    012.05

    016.04

    X3-ULTRA

    018.02

    017.05

    X3-AELIO

    004.04

    004.05

    X3-HYB-G4 PRO

    005.11

    005.12