Project design

    TOU Mode Operation Introduction

    Background

    TOU is short for ‘TIME OF USE’. TOU function is added to better help users optimize the assets of home power stations for different scenarios. This function helps users set the operation strategy of site on weekends, weekdays. According to the regulations of the local grid, so as to achieve asset optimization better under the premise of complying with the regulations of the power company.

    TOU Work Modes Introduction

    Self-Use(by default):

    PV energy is as self-sufficient as possible.

    The priority of PV energy is: load>battery>grid connection. Minimum SOC: The minimum SOC in this mode is functionally the same as the on-grid minimum SOC. The two values ​​do not interfere with each other. In the case of TOU, only this value is responded.

    Min SOC: Functions similarly to Grid-Connected Min SOC, values do not interfere. In TOU scenarios, only this value is considered.

     

    Battery hold:

    The battery does not charge or discharge. PV energy is only for self-use or output. The battery is charged only when the SOC is lower than the set minimum SOC. When the minimum SOC is reached, the charging stops.

     

    Peak-Shaving:

    After the load power reaches the threshold, the battery will begin to discharge. Threshold: Set the peak shaving limit, the battery is allowed to discharge after the imported power from the grid exceeds this value

    Peak Limit: Sets peak shaving limit, allowing battery discharge when grid consumption exceeds this

     

    Charging:

    PV will charge the battery as much as possible, and the user can choose whether to import from the grid

    Allow Grid Power: Yes/No

    Charge To: Target SOC for grid charging

    Max Charge Power: Max power for charging with both PV and grid

     

    Discharging:

    The system will discharge at the "percentage" rated power until the "discharge threshold", and then switch to Self-use

    AC Power: Max AC output power, can be % of rated or specified limit

    Discharge To: Discharge Cutoff SOC

     

     

    APP Settings (based on Cloud V6.3)

    1.     TOU main settings

    Operation Instructions:

    1.1 Select the Site              1.2 Entrance           1.3 Create TOU

    ①②Option to enable or disable TOU mode for this site

    ③④Click Intelligentthen Click TOU

    Create TOU

    1.4 Fill in information          1.5 Select           1.6 Choose Type

    Select the device you want to edit

    Choose the Period Type

    1.7 Select Cycle Type                        1.8 Select Time   1.9 Choose Work Mode

    Select Cycle Type to determine which TOU to use at different times

    ②③Add TOU and set different work modes for different time periodsand Min SOC be set at 10% by default

    1.4 Edit TOU             1.5 Set TOU successfully     1.6 Displayed on the inverter screen

     

     

     

     


     


    Web Settings (based on Cloud V6.3)

    1. TOU main settings

                

    Operation Instructions:

           In the navigation bar on the left, select the ‘device’

           Click the ‘Intelligence’ in the red circle

    ③④ On the TOU panel, click ‘Enter’. On the page that is displayed, click ‘Add Device’.

    1.1.2          Add device

    Operation Instructions:

    Click the ‘Confirm’, then click the ‘Details’ to check more information.

    1.2 Fill in the information and rules

    Operation Instructions:

    Click the ‘Edit’ if you want to alter your settings.

           Different date intervals can be set here, and a maximum of ten can be set

    You can choose to import the entire set directly, or it can be set by yourself

    The cycle type can be selected as either "Everyday" or "Workdays + Weekends".

           You can set the ‘Minimum SOC’ with a default setting of 10%.

    Operation Instructions:

        You can set the work mode for specific time periods here.

    Here you can delete.

     

    1.3 Add TOU rules

    Operation Instructions:

    ① Click Create New TOU and fill in the same content as before.

     

     

     

    Compatibility

    Inverter:

    Function

    Inverter Type

    TOU Function

    X1-IES

    X3-IES / X3-IES-P

    X1-Hybrid-G4

    X3-Hybrid-G4

    X1-Fit-G4

    X3-Fit-G4

    X1-Vast 5-10kW

    X3-HYB-G4 PRO

    X3-ULTRA

    A1-Hybrid-G2

    A1-AC-G2

    J3-ULTRA-LV

    J3-ULTRA

     

    Besides the inverter, the dongles hardware and firmware also need to be compatible, as listed below:

    Function

    Pocket Type

    Firmware Version

    Unlimited push

    Pocket WiFi 2.0/Plus(SX/SJ)

    ≥ 3.012.01

    Pocket WiFi 3.0(SV/SR)

    ≥ 3.012.01

    Pocket WiFi 3.0 (SS)

    > 3.037.04

    Pocket LAN 2.0(SL)

    ≥ 3.006.04

    Pocket LAN 3.0(SY)

    ≥ 3.006.04

    Pocket WiFi+LAN(SN)

    ≥ 1.002.09

    Pocket WiFi+4GM(SM)

    ≥ 1.002.14

     