Table 1 Application Scenario of ECC
Scheme |
Product/Component |
ECC |
Router |
Solax Cloud |
Remark |
Basic Operation |
SolaX X1-Micro 2 in 1 or SolaX X1-Micro 4 in 1 |
No |
No |
No |
Only used for basic power conversion without monitoring or advanced functions |
Monitoring and Data Analyse |
SolaX X1-Micro 2 in 1 or SolaX X1-Micro 4 in 1+router |
No |
Yes |
Yes |
Upload data to SolaX Cloud through router for monitoring and analyzing |
Zero export /interaction with external devices |
SolaX X1-Micro 2 in 1 or SolaX X1-Micro 4 in 1 + ECC + router |
Yes |
Yes |
Yes |
ECC manages the inverter to achieve zero control or control external device data to be uploaded to SolaX Cloud through the router |
Note:Zero export/External device interaction:For SolaX X1-Micro 2 in 1 and X1-Micro 4 in 1 series, if the inverter system needs to achieve zero export
(i.e. keeping excess power for local use without exporting to the grid) or needs to interact with other external devices (such as heat pumps), ECC is required to manage these functions. At the same time, for data monitoring and analysis, both ECC and the inverter need to be connected to a router, and the data is uploaded to SolaXCloud through the router.
Table 2 Application Scenario of ECC-PLC
Inverter Series |
Communication Method |
ECC/ECC-PLC Requirements |
ECC/ECC-PLC Connection Method |
Remarks |
A1-Micro 1 in 1 |
PLC |
ECC-PLC |
ECC-PLC is connected to ECC to match the whole system for use |
It is suitable for PLC version and needs ECC-PLC for system integration |
X1-Micro 2 in 1 |
WiFi |
ECC |
ECC is directly connected to the meter |
Applicable to WiFi version ECC management inverter and meter communication |
X1-Micro 4 in 1 |
WiFi |
ECC |
ECC is directly connected to the meter |
Applicable to WiFi version ECC management inverter and meter communication |
Note:Currently, we have developed A1-Micro 1 in 1, X1-Micro 2 in 1 and X1-Micro 4 in 1 series. 2 in 1 and 4 in 1 are applicable to WiFi version, and 1 in 1 is applicable to PLC version. For 2 in 1 and 4 in 1, ECC only needs to be connected to meter. For 1 in 1, ECC-PLC connects to ECC and matches to the whole system for use.
1. Download APP(SolaxCloud APP)
2. Create an Account
Step 1: Click register at the bottom of the login page to start creating an account. Select country and server site and select user roles to Improve the registration information and click to register.
Figure 1 Create an Account
3. Create a Site
Step 1: Click on the "➕" icon on the homepage to start creating the power station (for users who create the power station for the first time) .Click the "➕" icon in the upper right corner of the homepage to select Add Power Station from the drop-down menu (for users who have created power stations).
Figure 2 Create a Site
Step 2: The following boot page (4 pages in total) appears If you already know, you can click skip or I already know to add it.
Figure 3 Boot Page
Step 3: After adding the power station page, a window will pop up asking if you can allow SolaXCloud to obtain the location information of your mobile phone. Click allow for use only or allow for this use.
Step 4: Fill in the basic information of the power station, including the station name, installed capacity (range from 0 to 99999999), country/region, time zone, and location. Choose whether to enable default first display, daylight saving time, and decide whether to grant agent/installer permissions. Once completed, click Next.
Figure 4 Basic Information
4. Bind ECC in the added site
Figure 5 Bind ECC in the Added Site
5. Configure network for ECC
Figure 6 Configure network for ECC
Note: